Parameter | Data |
Label Specification | adhesive sticker, transparent or opaque |
Labeling Tolerance | ±0.5mm |
Capacity(pcs/min) | 15 ~ 30 |
Suit bottle size(mm) | L:20~200 W:20~150 H:0.2~120;Can be customized |
Suit label size(mm) | L: 15-100; W(H): 15-110 |
Machine Size(L*W*H) | ≈830*430*820 (mm) |
Pack Size(L*W*H) | ≈880*500*830 (mm) |
Voltage | 220V/50(60)HZ;Can be customized |
Power | 330W |
N.W (KG) | ≈45.0 |
G.W(KG) | ≈67.5 |
Label Roll | ID: Ø76mm;OD:≤240mm |
Air Supply | 0.4~0.6Mpa |
No. | Structure | Function |
1 | Label Tray | place the label roll. |
2 | Roller | wind the label roll. |
3 | Label Sensor | detect label. |
4 | Cylinder | drive labeling head to complete labeling. |
5 | Product Fixture | custom-made,fix product while labeling. |
6 | Labeling Head | get label and stick to pointed position. |
7 | Traction Device | driven by traction motor to draw the label. |
8 | Release Paper Recycling | recycle the release paper. |
9 | Emergency Stop | stop the machine if it runs wrong |
10 | Electric Box | place electronic configurations |
11 | Touch Screen | operation and setting parameters |
12 | Air Circuit Filter | filter water and impurities |
1 ) Control System:Japanese Panasonic control system , with high stability and extremely low failure rate.
2 ) Operation System:Color touch screen , directly visual interface easy operation.Chinese and English available . Easily to adjust all electrical parameters and have counting function , which is helpful for production management.
3) Detection System:Using German LEUZE/Italian Datalogic label sensor and Japanese Panasonic product sensor , which are sensitive to label and product , thus ensure high accuracy and stable labeling performance . Greatly saves labor .
4) Alarm Function : The machine will give an alarm when problem occur , such as label spill , label broken , or other malfunctions .
5) Machine Material : The machine and spare parts all use material stainless steel and anodized senior aluminum alloy , with high corrosion resistance and never rust .
6) Equip with a voltage transformer to adapt to local voltage